Added support for reading the TAMG ACPI table on Gigabyte mainboards. Fixed a small problem with HDD/SSD names (0 chars are trimmed now as well).
3 Version: MPL 1.1/GPL 2.0/LGPL 2.1
5 The contents of this file are subject to the Mozilla Public License Version
6 1.1 (the "License"); you may not use this file except in compliance with
7 the License. You may obtain a copy of the License at
9 http://www.mozilla.org/MPL/
11 Software distributed under the License is distributed on an "AS IS" basis,
12 WITHOUT WARRANTY OF ANY KIND, either express or implied. See the License
13 for the specific language governing rights and limitations under the License.
15 The Original Code is the Open Hardware Monitor code.
17 The Initial Developer of the Original Code is
18 Michael Möller <m.moeller@gmx.ch>.
19 Portions created by the Initial Developer are Copyright (C) 2009-2010
20 the Initial Developer. All Rights Reserved.
24 Alternatively, the contents of this file may be used under the terms of
25 either the GNU General Public License Version 2 or later (the "GPL"), or
26 the GNU Lesser General Public License Version 2.1 or later (the "LGPL"),
27 in which case the provisions of the GPL or the LGPL are applicable instead
28 of those above. If you wish to allow use of your version of this file only
29 under the terms of either the GPL or the LGPL, and not to allow others to
30 use your version of this file under the terms of the MPL, indicate your
31 decision by deleting the provisions above and replace them with the notice
32 and other provisions required by the GPL or the LGPL. If you do not delete
33 the provisions above, a recipient may use your version of this file under
34 the terms of any one of the MPL, the GPL or the LGPL.
39 using System.Collections.Generic;
40 using System.Globalization;
42 using System.Threading;
44 namespace OpenHardwareMonitor.Hardware.TBalancer {
45 internal class TBalancerGroup : IGroup {
47 private readonly List<TBalancer> hardware = new List<TBalancer>();
48 private readonly StringBuilder report = new StringBuilder();
50 public TBalancerGroup(ISettings settings) {
54 if (FTD2XX.FT_CreateDeviceInfoList(out numDevices) != FT_STATUS.FT_OK) {
55 report.AppendLine("Status: FT_CreateDeviceInfoList failed");
58 } catch (DllNotFoundException) { return; }
59 catch (ArgumentNullException) { return; }
60 catch (EntryPointNotFoundException) { return; }
61 catch (BadImageFormatException) { return; }
63 FT_DEVICE_INFO_NODE[] info = new FT_DEVICE_INFO_NODE[numDevices];
64 if (FTD2XX.FT_GetDeviceInfoList(info, ref numDevices) != FT_STATUS.FT_OK)
66 report.AppendLine("Status: FT_GetDeviceInfoList failed");
70 // make sure numDevices is not larger than the info array
71 if (numDevices > info.Length)
72 numDevices = (uint)info.Length;
74 for (int i = 0; i < numDevices; i++) {
75 report.Append("Device Index: ");
76 report.AppendLine(i.ToString(CultureInfo.InvariantCulture));
77 report.Append("Device Type: ");
78 report.AppendLine(info[i].Type.ToString());
80 // the T-Balancer always uses an FT232BM
81 if (info[i].Type != FT_DEVICE.FT_DEVICE_232BM) {
82 report.AppendLine("Status: Wrong device type");
87 FT_STATUS status = FTD2XX.FT_Open(i, out handle);
88 if (status != FT_STATUS.FT_OK) {
89 report.AppendLine("Open Status: " + status);
93 FTD2XX.FT_SetBaudRate(handle, 19200);
94 FTD2XX.FT_SetDataCharacteristics(handle, 8, 1, 0);
95 FTD2XX.FT_SetFlowControl(handle, FT_FLOW_CONTROL.FT_FLOW_RTS_CTS, 0x11,
97 FTD2XX.FT_SetTimeouts(handle, 1000, 1000);
98 FTD2XX.FT_Purge(handle, FT_PURGE.FT_PURGE_ALL);
100 status = FTD2XX.Write(handle, new byte[] { 0x38 });
101 if (status != FT_STATUS.FT_OK) {
102 report.AppendLine("Write Status: " + status);
103 FTD2XX.FT_Close(handle);
107 bool isValid = false;
108 byte protocolVersion = 0;
111 while (FTD2XX.BytesToRead(handle) == 0 && j < 2) {
115 if (FTD2XX.BytesToRead(handle) > 0) {
116 if (FTD2XX.ReadByte(handle) == TBalancer.STARTFLAG) {
117 while (FTD2XX.BytesToRead(handle) < 284 && j < 5) {
121 int length = FTD2XX.BytesToRead(handle);
123 byte[] data = new byte[285];
124 data[0] = TBalancer.STARTFLAG;
125 for (int k = 1; k < data.Length; k++)
126 data[k] = FTD2XX.ReadByte(handle);
128 // check protocol version 2X (protocols seen: 2C, 2A, 28)
129 isValid = (data[274] & 0xF0) == 0x20;
130 protocolVersion = data[274];
132 report.Append("Status: Wrong Protocol Version: 0x");
134 protocolVersion.ToString("X", CultureInfo.InvariantCulture));
137 report.AppendLine("Status: Wrong Message Length: " + length);
140 report.AppendLine("Status: Wrong Startflag");
143 report.AppendLine("Status: No Response");
146 FTD2XX.FT_Purge(handle, FT_PURGE.FT_PURGE_ALL);
147 FTD2XX.FT_Close(handle);
150 report.AppendLine("Status: OK");
151 hardware.Add(new TBalancer(i, protocolVersion, settings));
158 public IHardware[] Hardware {
160 return hardware.ToArray();
164 public string GetReport() {
165 if (report.Length > 0) {
166 StringBuilder r = new StringBuilder();
167 r.AppendLine("FTD2XX");
176 public void Close() {
177 foreach (TBalancer tbalancer in hardware)