Hardware/HDD/HDD.cs
author moel.mich
Sun, 26 Jun 2011 17:00:32 +0000
changeset 306 e9127c00ada1
parent 275 35788ddd1825
permissions -rw-r--r--
Added support for package level temperature sensors on new Intel Sandy Bridge CPUs.
moel@1
     1
/*
moel@1
     2
  
moel@1
     3
  Version: MPL 1.1/GPL 2.0/LGPL 2.1
moel@1
     4
moel@1
     5
  The contents of this file are subject to the Mozilla Public License Version
moel@1
     6
  1.1 (the "License"); you may not use this file except in compliance with
moel@1
     7
  the License. You may obtain a copy of the License at
moel@1
     8
 
moel@1
     9
  http://www.mozilla.org/MPL/
moel@1
    10
moel@1
    11
  Software distributed under the License is distributed on an "AS IS" basis,
moel@1
    12
  WITHOUT WARRANTY OF ANY KIND, either express or implied. See the License
moel@1
    13
  for the specific language governing rights and limitations under the License.
moel@1
    14
moel@1
    15
  The Original Code is the Open Hardware Monitor code.
moel@1
    16
moel@1
    17
  The Initial Developer of the Original Code is 
moel@1
    18
  Michael Möller <m.moeller@gmx.ch>.
moel@258
    19
  Portions created by the Initial Developer are Copyright (C) 2009-2011
moel@1
    20
  the Initial Developer. All Rights Reserved.
moel@1
    21
paulwerelds@218
    22
  Contributor(s): Paul Werelds
moel@1
    23
moel@1
    24
  Alternatively, the contents of this file may be used under the terms of
moel@1
    25
  either the GNU General Public License Version 2 or later (the "GPL"), or
moel@1
    26
  the GNU Lesser General Public License Version 2.1 or later (the "LGPL"),
moel@1
    27
  in which case the provisions of the GPL or the LGPL are applicable instead
moel@1
    28
  of those above. If you wish to allow use of your version of this file only
moel@1
    29
  under the terms of either the GPL or the LGPL, and not to allow others to
moel@1
    30
  use your version of this file under the terms of the MPL, indicate your
moel@1
    31
  decision by deleting the provisions above and replace them with the notice
moel@1
    32
  and other provisions required by the GPL or the LGPL. If you do not delete
moel@1
    33
  the provisions above, a recipient may use your version of this file under
moel@1
    34
  the terms of any one of the MPL, the GPL or the LGPL.
moel@1
    35
 
moel@1
    36
*/
moel@1
    37
moel@1
    38
using System;
paulwerelds@218
    39
using System.Collections.Generic;
moel@166
    40
using System.Globalization;
moel@1
    41
moel@1
    42
namespace OpenHardwareMonitor.Hardware.HDD {
moel@275
    43
  internal class HDD : Hardware {
moel@1
    44
moel@1
    45
    private const int UPDATE_DIVIDER = 30; // update only every 30s
moel@1
    46
moel@195
    47
    private readonly IntPtr handle;
moel@195
    48
    private readonly int drive;
moel@1
    49
    private int count;
moel@1
    50
moel@231
    51
    private readonly SMART.AttributeID temperatureID = SMART.AttributeID.None;
moel@231
    52
    private readonly SMART.AttributeID lifeID = SMART.AttributeID.None;
paulwerelds@218
    53
paulwerelds@218
    54
    private readonly Sensor temperatureSensor;
paulwerelds@218
    55
    private readonly Sensor lifeSensor;
paulwerelds@218
    56
moel@231
    57
    public HDD(string name, IntPtr handle, int drive, 
moel@231
    58
      SMART.AttributeID temperatureID, SMART.AttributeID lifeID, 
moel@275
    59
      ISettings settings) : base(name, new Identifier("hdd", 
moel@275
    60
          drive.ToString(CultureInfo.InvariantCulture)), settings)
paulwerelds@218
    61
    {
paulwerelds@218
    62
      this.handle = handle;
paulwerelds@218
    63
      this.drive = drive;
paulwerelds@218
    64
      this.count = 0;
moel@231
    65
      if (temperatureID != SMART.AttributeID.None) {
moel@231
    66
        this.temperatureID = temperatureID;
moel@231
    67
        this.temperatureSensor = new Sensor("HDD", 0, SensorType.Temperature,
moel@231
    68
          this, settings);
moel@231
    69
      }
moel@231
    70
moel@231
    71
      if (lifeID != SMART.AttributeID.None) {
moel@231
    72
        this.lifeID = lifeID;
moel@231
    73
        this.lifeSensor = new Sensor("Remaining life", 0, SensorType.Level,
moel@231
    74
          this, settings);
moel@231
    75
      }
paulwerelds@218
    76
paulwerelds@218
    77
      Update();
paulwerelds@218
    78
    }
moel@1
    79
moel@275
    80
    public override HardwareType HardwareType {
moel@165
    81
      get { return HardwareType.HDD; }
moel@1
    82
    }
moel@1
    83
moel@275
    84
    public override ISensor[] Sensors {
moel@1
    85
      get {
moel@231
    86
        if (lifeID != SMART.AttributeID.None)
paulwerelds@218
    87
          return new ISensor[] { lifeSensor };
paulwerelds@218
    88
moel@231
    89
        if (temperatureID != SMART.AttributeID.None)
paulwerelds@218
    90
          return new ISensor[] { temperatureSensor };
paulwerelds@218
    91
paulwerelds@218
    92
        return new ISensor[] {};
moel@1
    93
      }
moel@1
    94
    }
moel@1
    95
moel@275
    96
    public override void Update() {
moel@1
    97
      if (count == 0) {
paulwerelds@233
    98
        SMART.DriveAttribute[] attributes = SMART.ReadSmart(handle, drive);
paulwerelds@233
    99
moel@231
   100
        if (temperatureID != SMART.AttributeID.None &&
paulwerelds@233
   101
          Array.Exists(attributes, attr => attr.ID == temperatureID))
paulwerelds@218
   102
        {
paulwerelds@233
   103
          temperatureSensor.Value = Array
paulwerelds@233
   104
            .Find(attributes, attr => attr.ID == temperatureID)
paulwerelds@218
   105
            .RawValue[0];
paulwerelds@218
   106
        }
paulwerelds@218
   107
moel@231
   108
        if (lifeID != SMART.AttributeID.None &&
paulwerelds@233
   109
          Array.Exists(attributes, attr => attr.ID == lifeID))
paulwerelds@218
   110
        {
paulwerelds@233
   111
          lifeSensor.Value = Array
paulwerelds@233
   112
            .Find(attributes, attr => attr.ID == lifeID)
paulwerelds@218
   113
            .AttrValue;
paulwerelds@218
   114
        }
moel@1
   115
      } else {
paulwerelds@233
   116
        if (temperatureID != SMART.AttributeID.None)
paulwerelds@218
   117
          temperatureSensor.Value = temperatureSensor.Value;
paulwerelds@218
   118
paulwerelds@233
   119
        if (lifeID != SMART.AttributeID.None)
paulwerelds@218
   120
          lifeSensor.Value = lifeSensor.Value;
moel@1
   121
      }
moel@1
   122
moel@1
   123
      count++; count %= UPDATE_DIVIDER; 
moel@1
   124
    }
moel@1
   125
moel@298
   126
    public override void Close() {
moel@1
   127
      SMART.CloseHandle(handle);
moel@298
   128
      base.Close();
moel@1
   129
    }
moel@1
   130
moel@275
   131
    public override void Traverse(IVisitor visitor) {
moel@258
   132
      foreach (ISensor sensor in Sensors)
moel@258
   133
        sensor.Accept(visitor);
moel@258
   134
    }
moel@1
   135
  }
moel@1
   136
}