Hardware/CPU/AMD0FCPU.cs
author moel.mich
Thu, 05 Aug 2010 18:06:18 +0000
changeset 163 67be1c62f950
parent 122 3ef997c53b50
child 165 813d8bc3192f
permissions -rw-r--r--
Added ISA bus mutex support to the super IO detection.
moel@14
     1
/*
moel@14
     2
  
moel@14
     3
  Version: MPL 1.1/GPL 2.0/LGPL 2.1
moel@14
     4
moel@14
     5
  The contents of this file are subject to the Mozilla Public License Version
moel@14
     6
  1.1 (the "License"); you may not use this file except in compliance with
moel@14
     7
  the License. You may obtain a copy of the License at
moel@14
     8
 
moel@14
     9
  http://www.mozilla.org/MPL/
moel@14
    10
moel@14
    11
  Software distributed under the License is distributed on an "AS IS" basis,
moel@14
    12
  WITHOUT WARRANTY OF ANY KIND, either express or implied. See the License
moel@14
    13
  for the specific language governing rights and limitations under the License.
moel@14
    14
moel@14
    15
  The Original Code is the Open Hardware Monitor code.
moel@14
    16
moel@14
    17
  The Initial Developer of the Original Code is 
moel@14
    18
  Michael Möller <m.moeller@gmx.ch>.
moel@14
    19
  Portions created by the Initial Developer are Copyright (C) 2009-2010
moel@14
    20
  the Initial Developer. All Rights Reserved.
moel@14
    21
moel@14
    22
  Contributor(s):
moel@14
    23
moel@14
    24
  Alternatively, the contents of this file may be used under the terms of
moel@14
    25
  either the GNU General Public License Version 2 or later (the "GPL"), or
moel@14
    26
  the GNU Lesser General Public License Version 2.1 or later (the "LGPL"),
moel@14
    27
  in which case the provisions of the GPL or the LGPL are applicable instead
moel@14
    28
  of those above. If you wish to allow use of your version of this file only
moel@14
    29
  under the terms of either the GPL or the LGPL, and not to allow others to
moel@14
    30
  use your version of this file under the terms of the MPL, indicate your
moel@14
    31
  decision by deleting the provisions above and replace them with the notice
moel@14
    32
  and other provisions required by the GPL or the LGPL. If you do not delete
moel@14
    33
  the provisions above, a recipient may use your version of this file under
moel@14
    34
  the terms of any one of the MPL, the GPL or the LGPL.
moel@14
    35
 
moel@14
    36
*/
moel@14
    37
moel@14
    38
using System;
moel@14
    39
using System.Collections.Generic;
moel@14
    40
using System.Drawing;
moel@24
    41
using System.Diagnostics;
moel@14
    42
using System.Text;
moel@14
    43
moel@14
    44
moel@14
    45
namespace OpenHardwareMonitor.Hardware.CPU {
moel@31
    46
  public class AMD0FCPU : Hardware, IHardware {
moel@14
    47
moel@14
    48
    private string name;
moel@14
    49
    private Image icon;
moel@14
    50
moel@100
    51
    private int processorIndex;
moel@14
    52
    private uint pciAddress;
moel@14
    53
moel@77
    54
    private Sensor[] coreTemperatures;    
moel@14
    55
moel@24
    56
    private Sensor totalLoad;
moel@24
    57
    private Sensor[] coreLoads;
moel@24
    58
moel@26
    59
    private CPULoad cpuLoad;
moel@14
    60
moel@14
    61
    private const ushort PCI_AMD_VENDOR_ID = 0x1022;
moel@14
    62
    private const ushort PCI_AMD_0FH_MISCELLANEOUS_DEVICE_ID = 0x1103;
moel@14
    63
    private const uint THERMTRIP_STATUS_REGISTER = 0xE4;
moel@50
    64
    private const byte THERM_SENSE_CORE_SEL_CPU0 = 0x4;
moel@14
    65
    private const byte THERM_SENSE_CORE_SEL_CPU1 = 0x0;
moel@14
    66
moel@100
    67
    public AMD0FCPU(int processorIndex, CPUID[][] cpuid) {
moel@14
    68
moel@100
    69
      this.processorIndex = processorIndex;
moel@90
    70
      this.name = cpuid[0][0].Name;
moel@90
    71
      this.icon = Utilities.EmbeddedResources.GetImage("cpu.png");
moel@14
    72
moel@90
    73
      int coreCount = cpuid.Length;      
moel@14
    74
moel@24
    75
      totalLoad = new Sensor("CPU Total", 0, SensorType.Load, this);
moel@26
    76
        
moel@77
    77
      float offset = -49.0f;
moel@63
    78
moel@63
    79
      // AM2+ 65nm +21 offset
moel@90
    80
      uint model = cpuid[0][0].Model;
moel@63
    81
      if (model >= 0x69 && model != 0xc1 && model != 0x6c && model != 0x7c) 
moel@63
    82
        offset += 21;
moel@63
    83
moel@90
    84
      // check if processor supports a digital thermal sensor 
moel@90
    85
      if (cpuid[0][0].ExtData.GetLength(0) > 7 && 
moel@90
    86
        (cpuid[0][0].ExtData[7, 3] & 1) != 0) 
moel@90
    87
      {
moel@90
    88
        coreTemperatures = new Sensor[coreCount];
moel@90
    89
        for (int i = 0; i < coreCount; i++) {
moel@90
    90
          coreTemperatures[i] =
moel@134
    91
            new Sensor("Core #" + (i + 1), i, SensorType.Temperature,
moel@90
    92
              this, new ParameterDescription[] { 
moel@122
    93
                new ParameterDescription("Offset [°C]", 
moel@90
    94
                  "Temperature offset of the thermal sensor.\n" + 
moel@90
    95
                  "Temperature = Value + Offset.", offset)
moel@63
    96
          });
moel@90
    97
        }
moel@90
    98
      } else {
moel@90
    99
        coreTemperatures = new Sensor[0];
moel@26
   100
      }
moel@24
   101
moel@90
   102
      coreLoads = new Sensor[coreCount];
moel@90
   103
      for (int i = 0; i < coreCount; i++) 
moel@90
   104
        coreLoads[i] = new Sensor("Core #" + (i + 1), i + 1,
moel@90
   105
          SensorType.Load, this);     
moel@90
   106
moel@90
   107
      cpuLoad = new CPULoad(cpuid);
moel@26
   108
      if (cpuLoad.IsAvailable) {
moel@26
   109
        foreach (Sensor sensor in coreLoads)
moel@26
   110
          ActivateSensor(sensor);
moel@26
   111
        ActivateSensor(totalLoad);
moel@26
   112
      }
moel@14
   113
moel@14
   114
      pciAddress = WinRing0.FindPciDeviceById(PCI_AMD_VENDOR_ID,
moel@100
   115
        PCI_AMD_0FH_MISCELLANEOUS_DEVICE_ID, (byte)processorIndex);
moel@14
   116
moel@14
   117
      Update();                   
moel@14
   118
    }
moel@14
   119
moel@110
   120
    public override string Name {
moel@14
   121
      get { return name; }
moel@14
   122
    }
moel@14
   123
moel@110
   124
    public override Identifier Identifier {
moel@109
   125
      get { return new Identifier("amdcpu", processorIndex.ToString()); }
moel@14
   126
    }
moel@14
   127
moel@110
   128
    public override Image Icon {
moel@14
   129
      get { return icon; }
moel@14
   130
    }
moel@14
   131
moel@110
   132
    public override void Update() {
moel@42
   133
      if (pciAddress != 0xFFFFFFFF) {
moel@42
   134
        for (uint i = 0; i < coreTemperatures.Length; i++) {
moel@42
   135
          if (WinRing0.WritePciConfigDwordEx(
moel@42
   136
            pciAddress, THERMTRIP_STATUS_REGISTER,
moel@42
   137
            i > 0 ? THERM_SENSE_CORE_SEL_CPU1 : THERM_SENSE_CORE_SEL_CPU0)) {
moel@42
   138
            uint value;
moel@42
   139
            if (WinRing0.ReadPciConfigDwordEx(
moel@42
   140
              pciAddress, THERMTRIP_STATUS_REGISTER, out value)) {
moel@63
   141
              coreTemperatures[i].Value = ((value >> 16) & 0xFF) + 
moel@63
   142
                coreTemperatures[i].Parameters[0].Value;
moel@42
   143
              ActivateSensor(coreTemperatures[i]);
moel@42
   144
            } else {
moel@42
   145
              DeactivateSensor(coreTemperatures[i]);
moel@42
   146
            }
moel@24
   147
          }
moel@14
   148
        }
moel@24
   149
      }
moel@24
   150
moel@26
   151
      if (cpuLoad.IsAvailable) {
moel@26
   152
        cpuLoad.Update();
moel@26
   153
        for (int i = 0; i < coreLoads.Length; i++)
moel@26
   154
          coreLoads[i].Value = cpuLoad.GetCoreLoad(i);
moel@26
   155
        totalLoad.Value = cpuLoad.GetTotalLoad();
moel@25
   156
      }
moel@31
   157
    }   
moel@14
   158
  }
moel@14